Sci., 19, 1981, 40-45. umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 64 m; Column type: Capillary; Start T: 80 C; CAS no: 71432; Active phase: SE-30; Carrier gas: He; Data type: Kovats RI; Authors: Albaiges, J.; Guardino, X., Gas chromatographic-mass spectrometric identification of alkylcyclohexanes and cyclohexenes, Chromatographia, 13(12), 1980, 755-762. umn class: Standard non-polar; Column length: 12 ft; Column type: Packed; Start T: 150 C; CAS no: 71432; Active phase: SE-30; Substrate: Celaton (62-72 mesh); Data type: Kovats RI; Authors: Ashes, J.R.; Haken, J.K., Gas chromatography of homologous esters.

; Odell, A.L., Comparison of isothermal and non-linear temperature programmed gas chromatography.

This category only includes cookies that ensures basic functionalities and security features of the website.

; Tello, A.M.; Santiuste, J.M., Isothermal retention indices on poly (3,3,3-trifluoropropylmethylsiloxane) stationary phases, J. Chromatogr.

Slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising.

Chromatogr., 253, 1982, 179-198. umn class: Semi-standard non-polar; Column diameter: 0.23 mm; Column length: 100 m; Column type: Capillary; Start T: 100 C; CAS no: 71432; Active phase: Squalane; Carrier gas: N2; Data type: Kovats RI; Authors: Engewald, W.; Wennrich, L., Molekulstruktur und Retentionsverhalten. Soc.

J. Chromatogr., 15, 1992, 105-120. ass: Standard non-polar; Column diameter: 0.25 mm; Column length: 108 m; Column type: Capillary; Heat rate: 1 K/min; Start T: 35 C; End T: 200 C; CAS no: 71432; Active phase: OV-101; Phase thickness: 0.2 um; Data type: Linear RI; Authors: Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography.

(Rus. Chromatogr., 471, 1989, 227-236. ass: Standard polar; Column type: Capillary; CAS no: 71432; Active phase: Carbowax 20M; Data type: Normal alkane RI; Authors: Ramsey, J.D. ; Laub, R.J., Specific retention volumes and retention indices of selected hydrocarbon solutes with OV-3, OV-7, OV-11, OV-17, OV-22, and OV-25 polymethylphenylsiloxane solvents, J. Hi. Chromatogr., 586, 1991, 85-112. class: Standard polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Description: 0C(5min)=>fast=>60C(5min)=>4C/min=>220C(20min); CAS no: 71432; Active phase: CP-Wax 52CB; Phase thickness: 0.21 um; Data type: Linear RI; Authors: Madruga, M.S. deS. Chem., 61(9), 1982, 334-338. umn class: Semi-standard non-polar; Column type: Capillary; CAS no: 71432; Active phase: BP-5; Data type: Kovats RI; Authors: SGE, Guide to GC column selection, 2005. umn class: Semi-standard non-polar; Column length: 1 m; Column type: Packed; Start T: 160 C; CAS no: 71432; Active phase: Apiezon L; Substrate: Chromaton N-AW; Data type: Kovats RI; Authors: Kurbatova, S.V. Comm., 5, 1982, 325-328. umn class: Standard non-polar; Column diameter: 0.30 mm; Column length: 50 m; Column type: Capillary; Start T: 120 C; CAS no: 71432; Active phase: OV-101; Carrier gas: N2; Data type: Kovats RI; Authors: Gerasimenko, V.A. A, 761, 1997, 205-217. class: Standard non-polar; Column diameter: 0.2 mm; Column length: 100 m; Column type: Capillary; Description: 5C(10min)=>5C/min=>50C(48min)=>1.5C/min=>195C(91min); CAS no: 71432; Active phase: Petrocol DH-100; Carrier gas: He; Data type: Kovats RI; Authors: Haagen-Smit Laboratory, Procedure for the detailed hydrocarbon analysis of gasolines by single column high efficiency (capillary) column gas chromatography, SOP NO. Pyrolysis of heptane, Ind. Slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising.

Food Chem., 37(2), 1989, 418-420. ass: Standard non-polar; Column diameter: 0.5 mm; Column length: 50 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 40 C; End T: 170 C; Start time: 3 min; CAS no: 71432; Active phase: SE-30; Data type: Normal alkane RI; Authors: Heydanek, M.G.

Prod. Rostock Math. Food Chem., 37(3), 1989, 734-736. ass: Standard non-polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 3 K/min; Start T: 0 C; End T: 250 C; CAS no: 71432; Active phase: DB-1; Data type: Normal alkane RI; Authors: Habu, T.; Flath, R.A.; Mon, T.R.

For a better understanding of the chemical structure, an interactive 3D visualization of benzene is provided here. I. Calcul des coefficients d'activite relatifs et des indices de retention de quelques hydrocarbures aromatiques, Bull. ; Laub, R.J., Specific retention volumes and retention indices of selected hydrocarbon solutes with OV-3, OV-7, OV-11, OV-17, OV-22, and OV-25 polymethylphenylsiloxane solvents, J. Hi. 2. Chromatogr., 234, 1982, 285-302. umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 100 m; Column type: Capillary; Start T: 80 C; CAS no: 71432; Active phase: Squalane; Carrier gas: He; Data type: Kovats RI; Authors: Albaiges, J.; Guardino, X., Gas chromatographic-mass spectrometric identification of alkylcyclohexanes and cyclohexenes, Chromatographia, 13(12), 1980, 755-762. umn class: Semi-standard non-polar; Column length: 50 m; Column type: Capillary; Start T: 70 C; CAS no: 71432; Active phase: Squalane; Carrier gas: N2; Data type: Kovats RI; Authors: Nabivach, V.M.

Enthalpies of evaporation and thermodynamics chracteristics of sorption by stationary phases OV-101 and PEG-40M, Izvestia vysshikh uchebnykh zavedenii.

& Chromatogr. ; Flath, R.A., Volatile Components of Safflower, J. Agric. ; Laub, R.J., Specific Retention Volumes and Retention Indices of Selected Hydrocarbon Solutes with OV-1 and SE-30 Polydimethylsiloxane Solvents, J. Hi. & Chromatogr. Technol., 75(936), 2003, 47-53. ass: Standard polar; Column diameter: 0.32 mm; Column length: 50 m; Column type: Capillary; Heat rate: 2 K/min; Start T: 50 C; End T: 200 C; CAS no: 71432; Active phase: CP-Wax 52CB; Carrier gas: H2; Data type: Linear RI; Authors: Liu, T.-T.; Yang, T.-S.; Wu, C.-M., Changes of volatiles in soy sauce-stewed pork during cold storage and reheating, J. Sci. Chromatogr. A, 723, 1996, 77-91. umn class: Standard non-polar; Column diameter: 0.25 mm; Column length: 100 m; Column type: Capillary; Start T: 60 C; CAS no: 71432; Active phase: CP Sil 2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Estel, D.; Mohnke; Biermans; Rotzsche, The analysis of C4-C11 hydrocarbons in naphtha and reformate with a new apolar fused silica column, J. Hi. Anal. Sci., 9, 1971, 241-244. umn class: Semi-standard non-polar; Column diameter: 0.25 mm; Column length: 30 m; Column type: Capillary; Start T: 120 C; CAS no: 71432; Active phase: RTX-5; Carrier gas: N2; Phase thickness: 0.25 um; Data type: Kovats RI; Authors: Adamova, M.; Orinak, A.; Halas, L., Retention indices as identification tool in pyrolysis-capillary gas chromatography, J. Chromatogr.

.

Coffee Shop Promotion Ideas, D&d 5e Expanded Equipment, Celebrities That Weigh 70 Kg, Self Introduction Blog Example, Best Counter Depth Refrigerator Canada 2019, Self Introduction Blog Example, Robin Hume Obituary, Vancouver School District Jobs, Is Lucky Flickerman Related To Caesar Flickerman, Rideable Horses For Adoption Near Me, Why Won't My Powerpoint Slides Advance Automatically, Bmw Usa Commercial,